Rated capacity |
29.42 N{3 kgf}~980.7 N{100 kgf} |
Safe overload |
200 %R.C. |
Ultimate overload |
300 %R.C. |
Rated output |
2 mV/V±0.2 mV/V |
Non-linearity |
0.015 %R.O. |
Hysteresis |
0.015 %R.O. |
Repeatability |
0.02 %R.O. |
Creep |
0.02 %R.O./20 min (U2D1-3K : 0.03 %R.O./20 min) |
Creep recovery |
0.02 %R.O./20 min (U2D1-3K : 0.03 %R.O./20 min) |
Excitation, recommended |
12 V or less |
Excitation, maximum |
20 V |
Zero balance |
±0.1 mV/V |
Input resistance |
400 Ω ~ 450 Ω |
Output resistance |
345 Ω ~ 355 Ω |
Insulation resistance |
2 000 MΩ or more (DC50 V) (between bridge and main body) |
Temp. range, compensated |
-10 ℃ ~ 50 ℃ |
Temp. range, safe |
-10 ℃ ~ 50 ℃ |
Temp. effect on zero |
0.04 %R.O./10 ℃ |
Temp. effect on output |
0.012 %LOAD/10 ℃ |
Cable |
φ3.2, 4-cores shielded 30 cm cable directly attached. Cable end separated. |
Class of protection |
IP40 |
Material of element |
Alluminium alloy |
Durability |
1 000 00 times with rated load applied. |
Effect of eccentric load |
- The maximum size of loading plate : 400 mm x 600 mm - The center of loading plate and also center of load cell should be the same position - Error is withing 0.02 %R.O. applied with 1/2 of rated capacity at the position of 150 mm of eccentricity. |